FLAMMABILITY OF THERMOPLASTICS

VERTICAL AND HORIZONTAL BURN TESTS (UL94)

HB
Slow burning of horizontal test specimen
Burning rate <76 mm/min. for thickness lower than 3mm
Burning rate <38 mm/min. for thickness more than 3mm

V - 0
The burning of vertical test specimens, to be over within
10 sec. after the application of the test flame.
Not have any specimens that drip flaming particles.

V - 1
The burning of vertical test specimens, to be over within
30 sec. after the application of the test flame.
Not have any specimens that drip flaming particles.

V - 2
The burning of vertical test specimens, to be over within
30 sec. Be permitted to have specimens that drip flaming particles



GLOW WIRE TEST

This is a preferred test standard for electrical applications.Simulate the thermal stress that might be issued by a hot source. Evaluate flammability hazards and extinction capabilities.
The glow wire, brought to a given temperature (550, 650, 750, 850, 960°C) is applied on the sample positioned vertically by a 1 newton force for 30 sec. The measurement is the time elapsed between the application of the wire and the ignition of the sample and the control of the dripping.

The material passes the test under the following conditions;

  • Total absence of flame and non continuous glowing
  • In case of ignition, the same must last less than 30 sec. after remowing the wire.